Catheter Tipping Machines & Applications

Catheter Tipping Machines & Applications

Our Catheter Tipping Equipment Expertise

Today’s catheter delivery systems rely on increasingly complex shapes, constructions and polymers to deliver their intended treatment.  Many of the catheter tipping and end forming application complexities can only be consistently achieved through advanced technology and proper application of sound engineering principles.

Vante and PlasticWeld Systems catheter tipping equipment is the global standard for catheter tipping and end forming equipment.  Superior heating technology, proprietary thermal profiling and a defined customer engagement process lead by our experienced engineers – assure you get the best catheter tipping results possible.

Advantages of partnering with Vante and PlasticWeld Systems for RF catheter tipping and end forming include:

  • Wide range of technology options and experience to match the customer requirements with the optimal solution and price point.
  • Turnkey solutions which will allow you to make parts and validate your process fast!
  • Robust equipment that is proven in high volume environments, reduces cycle times and eliminates secondary operations like cutting flash.
  • Dedicated applications engineering and process development team to advise on product design and deliver turnkey process solutions.
  • Global service team that can respond quickly in your time of need
  • One stop shop for machines, tooling, development and prototypes
Learn More About Our Equipment Advantages
Supporting Catheter Tipping Machines & Applications Image

Applications

Taper Tip / Conical Tip
+
Taper/Conical
member bio

Taper/Conical

Tapered or conical tips are a standard configuration for many catheter applications, but don’t let their simple shape fool you.  Their precise external and internal geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

  • Tube OD Range: Tube sizes ranging from 2Fr up to 45Fr
  • Geometry Configurations: Including thin-walled tips, profiled ID transitions, thick walled and stepped OD’s.
  • Taper Lengths: Tip lengths ranging from 1mm up to 90mm
  • Materials: All thermoplastic polymers can be formed: including LDPE, HDPE, PE copolymers, PP, PU & PU blends, PEBAX, FEP, and many others.
  • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
  • Customized tooling enhancements to provide precise positioning of critical internal features

Contact us about your application


    Department

    Message

    bullet tips / closed end tips
    +
    Closed End Tip
    member bio

    Closed End Tip

    Closed end tips are a standard configuration for many catheter applications, but don’t let their simple shape fool you.  Their precise external geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

    • Tube OD Range: Tube sizes ranging from 2Fr up to 45Fr
    • Geometry Configurations: Including thin-walled tips, profiled ID transitions, thick walled and stepped OD’s.
    • Taper Lengths: Tip lengths ranging from 1mm up to 90mm
    • Materials: All thermoplastic polymers can be formed: including LDPE, HDPE, PE copolymers, PP, PU & PU blends, PEBAX, FEP, and many others.
    • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
    • Customized tooling enhancements to provide precise positioning of critical internal features

     


    Contact us about your application


      Department

      Message

      Neckdowns
      +
      Neckdown
      member bio

      Neckdown

      Neckdown tips are often used as an intermediate step to facilitate location of marker bands or other features in many catheters. Their precise external and internal geometric configurations are designed for consistent and reliable fitment to other components.  They require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

      • Tube OD Range: Tube sizes ranging from 2Fr up to 45Fr
      • Geometry Configurations: Including thin-walled tips, profiled ID transitions, thick walled and stepped OD’s.
      • Taper Lengths: Tip lengths ranging from 1mm up to 15mm
      • Materials: All thermoplastic polymers can be formed: including LDPE, HDPE, PE copolymers, PP, PU & PU blends, PEBAX, FEP, and many others.
      • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
      • Customized tooling enhancements to provide precise positioning of critical internal features

      Contact us about your application


        Department

        Message

        Catheter End Forming
        +
        Tip and End Forming
        member bio

        Tip and End Forming

        Tip and End Forming

        Non-symmetrical tips are becoming a standard configuration for many advanced catheter applications. Their precise, unique external geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

        • Tube OD Range: Tube sizes ranging from 4Fr up to 45Fr
        • Geometry Configurations: Including thin-walled tips, profiled ID transitions, thick walled and stepped OD’s.
        • Taper Lengths: Tip lengths ranging from 1mm up to 25mm
        • Materials: All thermoplastic polymers can be formed: including LDPE, HDPE, PE copolymers, PP, PU & PU blends, PEBAX, FEP, and many others.
        • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
        • Customized tooling enhancements to provide precise positioning of critical internal features

        Contact us about your application


          Department

          Message

          Radius tips Made on Vante and PlasticWeld Systems equipment
          +
          Radius Tip
          member bio

          Radius Tip

          Radius tips are a standard configuration for many catheter applications, but don’t let their simple shape fool you.  Their precise external and internal geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

          • Tube OD Range: Tube sizes ranging from 2Fr up to 45Fr
          • Geometry Configurations: Including thin-walled tips, profiled ID transitions, thick walled and stepped OD’s.
          • Taper Lengths: Tip lengths ranging from 1mm up to 10mm
          • Materials: All thermoplastic polymers can be formed: including LDPE, HDPE, PE copolymers, PP, PU & PU blends, PEBAX, FEP, and many others.
          • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
          • Customized tooling enhancements to provide precise positioning of critical internal features

          Contact us about your application


            Department

            Message

            Trachial and Angle Tips
            +
            Angle Tip
            member bio

            Angle Tip

            Angle tips are a standard configuration for many catheter applications, but don’t let their simple shape fool you.  Their precise external and internal geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

            • Tube OD Range: Tube sizes ranging from 10Fr up to 45Fr
            • Geometry Configurations: Including thin-walled tips, thick walled and stepped OD’s.
            • Taper Lengths: Tip lengths ranging from 1mm up to 20mm
            • Materials: Typical polymers include PVC, HDPE, LDPE and Pebax.
            • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
            • Customized tooling enhancements to provide precise positioning of critical internal features

            Contact us about your application


              Department

              Message

              Catheter Multi-Lumen Neckdown
              +
              Multi-Lumen
              member bio

              Multi-Lumen

              A growing number of advanced catheter applications utilize multiple lumens in a tube.  Tips are designed to close off some lumens while keeping others open.  Their precise external and internal geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

              • Tube OD Range: Tube sizes ranging from 2Fr up to 45Fr
              • Geometry Configurations: Including thin-walled tips, profiled ID transitions, thick walled and stepped OD’s.
              • Taper Lengths: Tip lengths ranging from 1mm up to 90mm
              • Materials: All thermoplastic polymers can be formed: including LDPE, HDPE, PE copolymers, PP, PU & PU blends, PEBAX, FEP, and many others.
              • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
              • Customized tooling enhancements to provide precise positioning of critical internal features

              Contact us about your application


                Department

                Message

                soft tips
                +
                Soft Tip
                member bio

                Soft Tip

                Soft, bonded tips are a standard configuration for many catheter applications.  Their precise external and internal geometric configurations, along with the need for a securely bonded interface, are critical to proper functioning of the catheter and patient comfort.  Soft tips require a precise, repeatable process to be formed accurately and reliable, maximum strength bonding. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

                • Tube OD Range: Tube sizes ranging from 2Fr up to 45Fr
                • Geometry Configurations: Including thin-walled tips, profiled ID transitions, thick walled and stepped OD’s.
                • Taper Lengths: Tip lengths ranging from 1mm up to 15mm
                • Materials: Most thermoplastic polymers can be formed: including PU & PU blends, PEBAX and many others.
                • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
                • Customized tooling enhancements to provide precise positioning of critical internal features

                Contact us about your application


                  Department

                  Message

                  Catheter Sheeth Tips
                  +
                  Sheath Tip
                  member bio

                  Sheath Tip

                  Sheath tips have special configuration requirements to assure proper functioning of the device.  Their precise external and internal geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

                  • Tube OD Range: Tube sizes ranging from 2Fr up to 45Fr
                  • Geometry Configurations: Including thin-walled tips, profiled ID transitions.
                  • Taper Lengths: Tip lengths ranging from 1mm up to 15mm
                  • Materials: All thermoplastic polymers can be formed: including LDPE, HDPE, PE copolymers, PP, PU & PU blends, PEBAX, FEP, and many others.
                  • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
                  • Customized tooling enhancements to provide precise positioning of critical internal features

                  Contact us about your application


                    Department

                    Message

                    dilator tips
                    +
                    Dilator Tip
                    member bio

                    Dilator Tip

                    Dilator tips require precise external and internal geometric configurations to perform properly. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

                    • Tube OD Range: Tube sizes ranging from 2Fr up to 45Fr
                    • Geometry Configurations: Including thin-walled tips, profiled ID transitions, thick walled and stepped OD’s.
                    • Taper Lengths: Tip lengths ranging from 1mm up to 90mm
                    • Materials: All thermoplastic polymers can be formed: including LDPE, HDPE, PE copolymers, PP, PU & PU blends, PEBAX, FEP, and many others.
                    • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
                    • Customized tooling enhancements to provide precise positioning of critical internal features

                    Contact us about your application


                      Department

                      Message

                      Catheter IV Tip Forming
                      +
                      IV Tips
                      member bio

                      IV Tips

                      IV tips are a standard and sometimes challenging catheter application. Their relatively small size and ultra thin-walled tubing creates a difficult challenge for most tipping platforms.  Their precise external and internal geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your IV tip production challenges.

                      • Tube OD Range: Tube sizes ranging from 22ga and up
                      • Geometry Configurations: Including thin-walled tips, profiled ID transitions
                      • Taper Lengths: Tip lengths ranging from 1mm up to 10mm
                      • Materials: Polymers generally include PTFE.
                      • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.
                      • Customized tooling enhancements to provide precise positioning of critical internal features

                      Contact us about your application


                        Department

                        Message

                        Catheter guidewire tips on Catheter Tip Forming Machine
                        +
                        Guidewire Tip
                        member bio

                        Guidewire Tip

                        Guidewire tips can be a challenge to produce.  The combination of wire core and thin external polymer sheath, along with precise external shapes require a precise, repeatable process to be formed accurately. A wide variation in sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

                        • OD Range: OD sizes ranging from 0.014” and larger
                        • Geometry Configurations: Including rounded tips
                        • Tip Lengths: Tip lengths ranging from 1mm and longer
                        • Materials: Polymers usually include: PU & PU blends, PEBAX and others.
                        • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.

                        Contact us about your application


                          Department

                          Message

                          CVC and Skiving
                          +
                          CVC
                          member bio

                          CVC

                          CVC tips require precise external geometric configurations, along with the need for a securely bonded interface, are critical to proper functioning of the catheter.  They require a precise, repeatable process to be formed accurately and while providing reliable, maximum strength bonds. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

                          • Tube OD Range: Tube sizes ranging from 2Fr and larger
                          • Geometry Configurations: standard radius tip thermally bonded to main catheter shaft
                          • Taper Lengths: Tip lengths ranging from 1mm up to 15mm
                          • Materials: Most thermoplastic polymers can be formed: including PU & PU blends, PEBAX and many others.
                          • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.

                          Contact us about your application


                            Department

                            Message

                            Catheter Urinary Tip with polished eyes
                            +
                            Urinary
                            member bio

                            Urinary

                            Urinary tips are a specialized subset of closed end tips.  Their precise external geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately while providing an ultra-smooth exterior surface to maximize patient comfort. A wide variation in tube sizes, along with a number of tip configurations and polymer choices adds extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

                            • Tube OD Range: Tube sizes ranging from 5Fr up to 24Fr
                            • Geometry Configurations: Including standard bullet tips, Coude, Tiemann and open tip configurations.
                            • Taper Lengths: Tip lengths ranging from 1mm up to 25mm
                            • Materials: Thermoplastic polymers typically include PVC and PU.
                            • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.

                            Contact us about your application


                              Department

                              Message

                              Catheter Angiographic Tip
                              +
                              Angiographic
                              member bio

                              Angiographic

                              Angioraphic tips require precise external geometric configurations, along with the need for a securely bonded interface, are critical to proper functioning of the catheter.  They require a precise, repeatable process to be formed accurately and while providing reliable, maximum strength bonds. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

                              • Tube OD Range: Tube sizes ranging from 2Fr up and larger
                              • Geometry Configurations: standard radius tip thermally bonded to main catheter shaft
                              • Taper Lengths: Tip lengths ranging from 1mm up to 15mm
                              • Materials: Most thermoplastic polymers can be formed: including PU & PU blends, PEBAX and many others.
                              • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.

                              Contact us about your application


                                Department

                                Message

                                Catheter Tracheal angle tips
                                +
                                Tracheal
                                member bio

                                Tracheal

                                Tracheal tips are a specialized subset of angle tips.  Their precise external and internal geometric configurations are designed for specific functions, and they require a precise, repeatable process to be formed accurately. A wide variation in tube sizes, tip configurations and polymer choices add extra layers of complexity to the tip forming process.  Vante and PlasticWeld diverse equipment options provide you with unmatched versatility to meet your specific production challenges.

                                • Tube OD Range: Tube sizes ranging from 10Fr up to 45Fr
                                • Geometry Configurations: angled ends, straight ends with radiused edges
                                • Taper Lengths: Tip lengths ranging from 1mm up to 20mm
                                • Materials: Typical polymers include PVC.
                                • Standard Machine Configurations: 1-up, 2-up and 4-up systems depending on project details.

                                Customized tooling enhancements to provide precise positioning of critical internal features


                                Contact us about your application


                                  Department

                                  Message

                                  Close

                                  Do you have an application you need help with?